describtion๏ผ
working voltage ๏ผDC6V-12V Power supply interface๏ผDC5.0
Test voltage๏ผ0-150V resolving power๏ผ0.05V
Test current๏ผ0-10A resolving power๏ผ0.05A
Capacity range๏ผ0-999.999Ah resolving power๏ผ0.001Ah
Power range๏ผ0.99999.9Wh resolving power๏ผ0.01Wh
Power range๏ผ0-2999.9ฮฉ resolving power๏ผ0.01ฮฉ
resist Model around๏ผ0-999.9ฮฉ resolving power๏ผ0.01ฮฉ
temperature range ๏ผ0-99โ resolving power:1โ
Timing range๏ผ999:59๏ผ59 resolving power๏ผ1second
Cooling power of fan๏ผ<150W
Fan control threshold ๏ผtemperature>40โ๏ผThe fan turns on automatically
Standby reminder threshold๏ผ<2W/0.5h
Timing function๏ผ>0.5WJust started timing
Input interface๏ผ20AHigh current bite screw column ใA type USBย Mini USB ใMicro USB ใType-C USB
Refresh time๏ผ>500ms/second
Measurement rate๏ผabout0.5second/second
Set overrun alarm mode:ย Interface warning and buzzer alarm
Voltage out of limit automatic stop discharge setting range๏ผ0-150V
Current out of limit automatic stop discharge setting range๏ผ0-10A
Setting range of power overrun automatic stop discharge๏ผ0-150W
Display screen type๏ผLCMBlack font green backlight display
size๏ผ149x98x80mm/195x105x135mm๏ผpacking๏ผ
System self consumption current๏ผ<1.5A
working temperature ๏ผ-10-60โ
Working humidity๏ผ10-80๏ผNo condensation๏ผ
usage method๏ผ
1.input voltage x electric currentโค150W๏ผ
2.Power on the load Coarse tuning and fine tuning knob zeroing๏ผ Turn counterclockwise to the end๏ผ๏ผ
3.Long press the mode button to clear all data๏ผ
4.Connect the tested power supply ๏ผIt is preferred to use the fine tuning knob to slowly adjust the discharge current ใWhen the fine adjustment cannot meet the current value, return the fine adjustment to zero๏ผ Slowly adjust the coarse adjustment knob ๏ผDo not cooperate with fine adjustment until the required current value is reached๏ผ
5.It is recommended to set the cut-off voltage during battery discharge test ๏ผ Voltage ๏ผInput lower limit ๏ผAvoid battery damage due to discharge๏ผ
Function description of mode button๏ผ
1.Click to switch the display interfaces๏ผ
2.stay2-4The key operation functions under the interface are as follows:๏ผ
โ Long press all records to clear๏ผ
โกDouble click capacity๏ผ Ah ๏ผReset reset๏ผ
โขThree strike electric quantity๏ผ Wh ๏ผfReset reset๏ผ
โฃFour strike electric quantity๏ผ00:00:00๏ผReset reset๏ผ
โคSeven consecutive blows at no load ๏ผAccurate calibration and zeroing of current zero position in the current temperature illusion ๏ผIt is conducive to accurate measurement at low current๏ผ
All parameters are restored to the factoryใ
3.Interface6.7.9.11.13The operation functions of the lower key are as follows:๏ผ
โ Double click the parameter value to increase ๏ผDouble click and long press to increase the parameters continuously๏ผ
โกThree hit parameter value decreases ๏ผAfter three hits, the long press parameter continues to decrease๏ผ